DB-25 to DB-25, straight-thru
DB-25 DB-25
 M / F M / F
 -------- --------
 2 TxD ------------ TxD 2
 3 RxD ------------ RxD 3
 7 Gnd ------------ Gnd 7
 20 DTR ------------ DTR 20
 6 DSR ------------ DSR 6
 8 DCD ------------ DCD 8
 4 RTS ------------ RTS 4
 5 CTS ------------ CTS 5
DB-25 to DB-25, crossover
DB-25 DB-25
 M / F M / F
 -------- --------
 2 TxD ------------ RxD 3
 3 RxD ------------ TxD 2
 7 Gnd ------------ Gnd 7
 20 DTR --------|--- DSR 6
 |--- DCD 8
 6 DSR ---|-------- DTR 20
 8 DCD ---|
 4 RTS ------------ CTS 5
 5 CTS ------------ RTS 4
DB-25 to DB-9, straight-thru
DB-25 DB-9
 M / F M / F
 -------- --------
 2 TxD ------------ TxD 3
 3 RxD ------------ RxD 2
 7 Gnd ------------ Gnd 5
 20 DTR ------------ DTR 4
 6 DSR ------------ DSR 6
 8 DCD ------------ DCD 1
 4 RTS ------------ RTS 7
 5 CTS ------------ CTS 8
DB-25 to DB-9, crossover
DB-25 DB-9
 M / F M / F
 -------- --------
 2 TxD ------------ RxD 2
 3 RxD ------------ TxD 3
 7 Gnd ------------ Gnd 5
 20 DTR --------|--- DCD 1
 |--- DSR 6
 6 DSR ---|-------- DTR 4
 8 DCD ---|
 4 RTS ------------ CTS 8
 5 CTS ------------ RTS 7
RJ-45 (Cyclades) to DB-25, straight-thru
RJ-45 DB-25
 Cyclades M / F
 -------- --------
 3 TxD ------------ TxD 2
 6 RxD ------------ RxD 3
 4 Gnd ------------ Gnd 7
 2 DTR ------------ DTR 20
 8 DSR ------------ DSR 6
 7 DCD ------------ DCD 8
 1 RTS ------------ RTS 4
 5 CTS ------------ CTS 5
RJ-45 (Cyclades) to DB-25, crossover
RJ-45 DB-25
 Cyclades M / F
 -------- --------
 3 TxD ------------ RxD 3
 6 RxD ------------ TxD 2
 4 Gnd ------------ Gnd 7
 2 DTR --------|--- DSR 6
 |--- DCD 8
 7 DCD ---|-------- DTR 20
 8 DSR ---|
 1 RTS ------------ CTS 5
 5 CTS ------------ RTS 4
RJ-45 (Cyclades) to DB-9, straight-thru
RJ-45 DB-9
 Cyclades M / F
 -------- --------
 3 TxD ------------ TxD 3
 6 RxD ------------ RxD 2
 4 Gnd ------------ Gnd 5
 2 DTR ------------ DTR 4
 8 DSR ------------ DSR 6
 7 DCD ------------ DCD 1
 1 RTS ------------ RTS 7
 5 CTS ------------ CTS 8
RJ-45 (Cyclades) to DB-9, crossover
RJ-45 DB-9
 Cyclades M / F
 -------- --------
 3 TxD ------------ RxD 2
 6 RxD ------------ TxD 3
 4 Gnd ------------ Gnd 5
 2 DTR --------|--- DCD 1
 |--- DSR 6
 7 DCD ---|-------- DTR 4
 8 DSR ---|
 1 RTS ------------ CTS 8
 5 CTS ------------ RTS 7
RJ-45 (Cyclades) to RJ-45 (Cyclades), straight-thru
RJ-45 RJ-45 
 Cyclades Cyclades 
 -------- --------
 3 TxD ------------ TxD 3
 6 RxD ------------ RxD 6
 4 Gnd ------------ Gnd 4
 2 DTR ------------ DTR 2
 8 DSR ------------ DSR 8
 7 DCD ------------ DCD 7
 1 RTS ------------ RTS 1
 5 CTS ------------ CTS 5
RJ-45 (Cyclades) to RJ-45 (Cyclades), crossover
RJ-45 RJ-45 
 Cyclades Cyclades 
 -------- --------
 3 TxD ------------ RxD 6
 6 RxD ------------ TxD 3
 4 Gnd ------------ Gnd 4
 2 DTR --------|--- DCD 7
 |--- DSR 8
 7 DCD ---|-------- DTR 2
 8 DSR ---|
 1 RTS ------------ CTS 5
 5 CTS ------------ RTS 1
RJ-45 (Cyclades) to RJ-45 (Sun/Cisco), straight-thru
RJ-45 RJ-45 
 Cyclades Sun/Cisco
 -------- ---------
 3 TxD ------------ TxD 3
 6 RxD ------------ RxD 6
 4 Gnd --------|--- Gnd 4
 |--- Gnd 5
 2 DTR ------------ DTR 2
 7 DCD ------------ DSR 7
 1 RTS ------------ RTS 1
 5 CTS ------------ CTS 8
RJ-45 (Cyclades) to RJ-45 (Sun/Cisco), crossover
RJ-45 RJ-45 
 Cyclades Sun/Cisco
 -------- ---------
 3 TxD ------------ RxD 6
 6 RxD ------------ TxD 3
 4 Gnd --------|--- Gnd 4
 |--- Gnd 5
 2 DTR ------------ DSR 7
 7 DCD ------------ DTR 2
 1 RTS ------------ CTS 8
 5 CTS ------------ RTS 1
RJ-45 (Cyclades) to MMJ (DEC), crossover
RJ-45 MMJ 
 Cyclades DEC
 -------- ---------
 3 TxD ------------ RxD 5
 6 RxD ------------ TxD 2
 4 Gnd --------|--- Gnd 3
 |--- Gnd 4
 2 DTR ------------ DSR 6
 7 DCD ------------ DTR 1
DB-9 to DB-9, crossover
DB-9 DB-9
 M / F M / F
 -------- --------
 1 ----+--------- 4 (1 and 6 connected to 4)
 6 ----+
 2 -------------- 3 (2 connected to 3)
 3 -------------- 2 (3 connected to 2)
 4 --------+----- 1 (4 connected to 1 and 6)
 +----- 6
 5 -------------- 5 (5 connected to 5)
 7 -------------- 8 (7 connected to 8)
 8 -------------- 7 (8 connected to 7)
 
                     
                     
                     
                
        