PRODUCTS | NOTES | RELEASE VERSION AND DATE | SOFTWARE DOWNLOAD |
---|---|---|---|
IS-UNITY-DP | Web, Emerson Protocol, SN Sensor, LIFE™ Services, SNMP, Modbus RTU/TCP, BACnet MSTP/IP, SMTP, SMS, and Telnet for many Liebert AC Power and Liebert iCOM v4 Thermal Management units Unity Release Notes 7.1.0.0 |
7.1.0.0_00044 Mar 2018 | IS-UNITY 7.1.0.0_00044 |
IS-UNITY-SNMP | Web, Emerson Protocol, LIFE™ Services, SNMP, SMTP, SMS, and Telnet for many Liebert AC Power and Liebert iCOM v4 Thermal Management | ||
IS-UNITY-LIFE | Web, Emerson Protocol, SN Sensor, and LIFE™ Services for many Liebert AC Power and Liebert iCOM v4 Thermal Management units | ||
IS-WEBCARD | Web, SNMP for HID9 IS-WEBCARDs in small UPS units Release Notes |
5.300.7_101214 November 2016 |
IS-WEBCARD_HID9_ 5.300.7_101214 |
IS-WEBLB | IS-WEBLB Card found in Liebert NX UPS units | 5.010.5_101214 November 2016 |
IS-WEBLB_HID10_ 5.010.5_101214 |
IS-WEBADPT | Web, SNMP, Modbus RTU, and Telnet for Liebert AC Power and Thermal Management units that have no IntelliSlot card ports | 5.2A0.6_101214 November 2016 |
IS-WEBADPT_HID10_ HID10_5.2A0.6_101214 |
RPC-1000 | Web, Emerson protocol, SN Sensor, SNMP and Telnet for Liebert MPX and MPH Rack PDU | 4.D40.2_101213 November 2016 |
RPC_HID16_ 4.D40.2_101213 |
IS-WEBRT3 | IS-WEBRT3 Card found in Liebert PSI UPS units | 2.40.CP504E.ABE.24 January 2014 |
IS-WEBRT3_ 2.40. CP504E.ABE.24 |
IS-IPBML | Modbus TCP, BACnet IP, and Web for Liebert APM, NXC, NXR and iCOM v4 Thermal Management units | 5.1E0.5_089394 February 2015 | IS-IPBML_HID10_ 5.1E0.5_089394 |
IS-WEBL | Web, SNMP, SMS, SMTP, Telnet, and Emerson Protocol for some Liebert AC Power and iCOM v4 Thermal Management units prior to Nov. 201 | 5.280.5_089394 February 2015 |
IS-WEBL_HID10_ 5.280.5_089394 |
IS-WEBLBDS | IS-WEBLBDS Card found in Liebert iCOM v3 air units | 5.010.2_089947 February 2015 | IS-WEBLBDS_HID10_ 5.050.0_068484 |
IS-IPBMS | Modbus TCP and Web Configuration support for Liebert Power Distribution Units with iCOM controllers (FDC, RDC and RX after Jan 2012; EXC, FPC, and PPC after Apr 2012) | 5.0F0.2_092876 June 2015 |
IS-IPBMS_ HID10_ 5.0F0.2_092876 |
IS-IPBMX | Modbus TCP and Web Configuration support for Alber BDSU50 and Liebert NXL. Note: Liebert NXL is now using the IS-UNITY-DP card as a form, fit, and feature replacement for this card. | 6.1C0.4_076551 June 2013 |
IS-IPBMX_HID14_ 6.1C0.4_076551 |
IS-WEBS | Web, SNMP, SMS, SMTP, Telnet, and Emerson Protocol for Liebert Power Distribution Units with iCOM controllers (FDC, RDC and RX after Jan 2012; EXC, FPC, and PPC after Apr 2012) | 5.0K0.1_092876 June 2015 |
IS-WEBS_HID10_ 5.0K0.1_092876 |
IS-WEBX | Web, SNMP, SMS, SMTP, Telnet, and Emerson Protocol for Alber BDSU50 and Liebert NXL. Note: Liebert NXL is now using the IS-UNITY-DP card as a form, fit, and feature replacement for this card. | 6.1J0.2_076551 May 2011 |
IS-WEBX_HID14_ 6.1J0.2_076551 |
OCWEB-ADPT | OCWEB Adapter found in large Air, UPS & Power units, running version 3.x | 3_121_1 January 2010 |
OCWEB-ADPT_HID5_ 3_121_1 |
OCWEBCARD | OC-WEB Card found in small UPS units | 2.400.3 June 2010 |
OCWEBCARD HID3 2.400.3 |