Liebert DSE Free Cooling System, 50-165kW
The Liebert DSE is the industry's first pumped refrigerant economization system designed specifically for data centers. Ideal for companies seeking sustainable solutions, it provides up to 50% higher efficiency than traditional systems - and it uses no water. Its advanced controls automate economization to get the most free cooling in any environment.
Produkt wurde in Ihrem Dashboard gespeichert
Sie haben dieses Produkt in Ihrem Dashboard gespeichert, um es ggf. später anzeigen zu können. Wenn Sie das Produkt nicht mehr speichern möchten, können Sie es jederzeit wieder aus Ihrem Dashboard entfernen.
Zum Speichern bitte anmelden beziehungsweise Konto erstellen
- Government
- Banking, Financial and Insurance
- Broadcast and Entertainment
- Data Center/Colocation/Hosting
- Professional Services
- Telecom
Liebert DSE Free Cooling System, 50-165kW
The Liebert DSE is the industry's first pumped refrigerant economization system designed specifically for data centers. Ideal for companies seeking sustainable solutions, it provides up to 50% higher efficiency than traditional systems - and it uses no water. Its advanced controls automate economization to get the most free cooling in any environment.
- Government
- Banking, Financial and Insurance
- Broadcast and Entertainment
- Data Center/Colocation/Hosting
- Professional Services
- Telecom
Technische Daten
The Liebert DSE is a free cooling economization system with backup DX compressor, that achieves the industry’s highest efficiency operation – up to 50% more efficient than legacy technologies. The Liebert DSE system was recently approved by the State of California as a prescriptive option for economization under Title 24. The system includes several components – a pumped refrigerant economizer, a micro-channel condenser and an indoor CRAC unit. The system operates in free cooling or partial free cooling mode, depending upon outdoor temperatures. When criteria for economization are met, the compressors turn off and the refrigerant pump turns on to move the refrigerant through the system to reject the heat of the data center, using only a fraction of the power of a compressor. Automated economization, controlled by advanced Liebert iCOM controls, maximizes the number of free cooling hours by enabling economization whenever conditions warrant, even at night. It also eliminates the use of water. In contrast, a cooling system with a water economizer uses an average of 4 million gallons of water per year for a data center with an IT load of 1MW. Additionally, the Liebert DSE system protects against outside air contamination and reduces system wear and tear by eliminating air dampers and louvers. As a self-contained solution, Liebert DSE system is highly scalable. It also offers higher reliability than chilled water systems, because it does not use chillers, pumps, piping and other potential points of failure.
Air-cooled free-cooling system with water-free economization, a rapidly deployable configuration and advanced Liebert iCOM thermal controls to optimize each unit and harmonize the operation of multiple units for temperature and airflow. Highly scalable and modular design accommodates changing IT loads and is ideal for upgrading outdated or inefficient cooling systems.
DA050, 50kW
|
||||||
---|---|---|---|---|---|---|
166 [49] | 166 [49] | 7000 | 76 in | 77 in | 35 in | 1590 lb |
Weitere Produktinformationen anzeigen | ||||||
DA080, 80kW
|
||||||
285 [84] | 277 [81] | 9600 | 76 in | 100 in | 35 in | 2200 lb |
Weitere Produktinformationen anzeigen | ||||||
DA085, 85kW
|
||||||
307 [90] | 297 [87] | 10,400 | 76 in | 100 in | 35 in | 2250 lb |
Weitere Produktinformationen anzeigen | ||||||
DA125, 125kW
|
||||||
443 [130] | 443 [130] | 18,000 | 94 in | 144 in | 47 in | 3465 lb |
Weitere Produktinformationen anzeigen | ||||||
DA150, 150kW
|
||||||
563 [165] | 542 [159] | 18,000 (24,000 optional) | 94 in | 144 in | 47 in | 3574 lb |
Weitere Produktinformationen anzeigen | ||||||
DA165, 165kW
|
||||||
602 [177] | 566 [166] | 20,000 (24,000 optional) | 94 in | 144 in | 47 in | 3574 lb |
Weitere Produktinformationen anzeigen | ||||||
DA250, 250 kW
|
||||||
853 [250] | 853 [250] | 36,500 | 132 1/8 in | 120 1/8 in | 83 1/2 in | 6285 lb |
Weitere Produktinformationen anzeigen | ||||||
DA265, 265 kW
|
||||||
905 [265] | 905 [265] | 36,500 | 134 1/8 in | 120 1/8 in | 83 1/2 in | 6455 lb |
Weitere Produktinformationen anzeigen |
Vorteile
Leistungsmerkmale
- Liebert® DSE 50-165 kW 60 User Manual (SL-18933)
- Liebert® DSE 50-165 kW 14-47 Tons System Design Manual
- Liebert® DSE 250-265 kW Thermal Management System Installer User Guide SL-18945
- Liebert® iCOM™ Installer/User Guide (SL-31075)
- Liebert® MCV 60Hz High Density Microchannel Condenser Installer-User Guide
- Liebert® EconoPhase 14 to 72 Ton (50 to 250 kW) 50 and 60 Hz Installer User Guide
- Free Cooling Economizer Tool
*Gehen Sie auf die Produktseite des jeweiligen Modells, indem Sie den Namen des Modells oben in der Datentabelle angeben, um Downloads zu den einzelnen Modellen anzuzeigen.