Liebert® TFX Power Distribution Unit
Liebert® TFX, 200kVA
Specifications
Technical Specifications
Liebert® TFX, 200kVA
The Liebert TFX is a floor-mounted power distribution unit offering reliable single or two-stage power in small to mid-sized data centers, server rooms, network closets, and modular and containerized deployments. It is ideally suited for edge data centers and other remote facilities. The compact 36-inch-depth cabinet offers easy mobility. It fits through doors or in freight elevators, and can be installed next to walls or in corners or alcoves. The unit features an intelligent distribution power monitoring (DPM) system with a 9-inch color touchscreen display and an easy-to-program navigation menu to manage equipment loads. The power monitoring system integrates with your BMS to provide remote monitoring of critical power measurements and alarms. Isolated panelboards allow your engineers to safely perform onsite maintenance on low-voltage monitoring components without powering down the unit. The made-to-order PDU is customized according to your power needs, and shipped to you with panelboards and subfeeds configured to your specifications. The Liebert TFX accommodates both single and dual-stage distribution setups, and can be supplemented with Liebert® FLX expansion cabinets for additional power capacity.
Warranty : One Year Limited Warranty Against Defects in Material and Workmanship- Product Overview
- Capacity
- 200kVA
- Input Voltage
- 600VAC, 480VAC
- Output Voltage
- 208Y/120VAC, 415Y/240VAC
- Output Options
- Flexible using Subfeed and/or Panelboards
- Distribution Options
- Flexible using Subfeed and/or Panelboards
- Power Description
- Transformer
- Available in Aluminum, Copper with K-Factor ratings ranging K4-K20
- Frequency
- 60Hz
- Input Breaker Rating
- 350A
- Interfaces/Ports
- Interface Options
- Optional communications card (Vertiv RDU101)
- Protocols
- With optional RDU101: HTTP/HTTPS, Vertiv Protocol, Email, SMS, SNMP v1/v2c/v3, BACnet IP and Modbus TCP output. BACnet/MSTP and Modbus/RTU support
- Control Panel
- 9.0" Color touchscreen display
- Service Access
- Top and Front access are required and side access is recommended
- Cable Access
- Industry leading Top and Bottom in the same frame
- Management
- Listings
- Industries first dual-UL Bi-National listed as a complete system under UL 60950-1 and UL 62368-1
- Operational Conditions
- Operating Temperature
- 32 F - 104 F / 0 C - 40 C
- Cooling
- Convection
- Miscellaneous
- General
- ANSI/IEEE C62.41 Category B1-B3, FCC Part 15 Class A,
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.